Client:
TOTAL- Vern sur Seiche Country:
France
Total have confidence on Meci for the supply of measuring system compliant with the Measuring Instrument Directive MID. The metering is made during the transfer of various petroleum products from the refinery of Donges to Vern sur Seiche storage.
The measuring system provided by Meci is conform to EC Type Examination Certificate including a Coriolis mass flowmeter , flow computer CDN12 and associated instrumentation.
Key points:
Multi products metering
Measuring system conform to EC Type Examination Certificate MID
Operating Conditions:
Measured medium : refined hydrocarbons
Pressure : 20 Bar
Temperature : 0°C à 40°C
Flow rate : 67 à 500 m3/h
Accuracy : +/- 0,3 %